description
Model |
EW-DP60W-52 |
|
Output |
Group Of Output |
1 |
DC Voltage |
52VDC |
|
Default Output Voltage |
0-1.15A |
|
Stabilized Voltage Precision |
±1% |
|
Line Regulation |
±1% |
|
Load Regulation |
±1% |
|
Temperature Coefficient |
±0.03%/℃ |
|
Output Start Time |
≤3.0S (120Vac input, Full load); ≤2.0S (220Vac input, Full load) |
|
Output Hold Time |
≥10mS(120Vac input, Full load); ≥20mS(220Vac input, Full load) |
|
Voltage Overshoot |
<5.0% |
|
Input |
Input Voltage Range |
90VAC~264VAC |
Input Rated Voltage Range |
100VAC~240VAC |
|
Frequency Range |
47Hz~63Hz |
|
Efficiency |
90% |
|
Input Current |
<1A |
|
Inrush Starting Current |
<40A@300Vac Cold start; |
|
Leakage Current |
input to output less than 0.25mA |
|
Operation Environment |
Operation Temperature And Humidity |
-20℃~65℃; 20%~90%RH No condensing |
Storage Temperature And Humidity |
-40℃~85℃; 5%~95%RH No condensing |
|
Safety And EMC Standard |
Security Standard |
GB4943/EN60950 |
Dielectric Strength |
Input—Output:3KVac/10mA; Input—Case:1.5KVac/10mA; Output—Case:0.5KVDC/10mA Time for each testing is 1min. |
|
Insulation Resistance |
Input-Output: 100M ohms; Input-Case: 100M ohms; Output-Case: 100M ohms; |
|
Electromagnetic Interference |
EN55022 Class A |
|
Harmaonic Current |
IEC61000-3-2 class A equipment requirements |
|
Electromagnetic interference Immunity |
EN61000-4-2,4,5,6,8,11 ENV50204, class A heavy industry standard |
|
Others |
Design MTBF |
100,000Hrs AT 25℃, MIL-217 Method 2 Components Stress Method |
Product size(L*W*H) |
173*72.5*33mm |