description
Model |
EW-PI480W-48 |
|||
Output |
Group of Output |
1 |
||
DC Voltage |
DC 48V |
|||
Default Output Voltage |
0-10A |
|||
Output Rated Current |
10A |
|||
Output Current Range |
0-10A |
|||
Output Rated Power |
480W |
|||
Total Peak Output Power |
Up to 480W (Sustainable time 10S/220VAC) |
|||
Peak Output Current |
10A(Sustainable time 10S/220VAC) |
|||
Ripple noise |
Peak – Peak ≤100mV (Test Method: The terminal shall be in parallel with capacitance of 0.1uF and 47uF, testing at 20MHz) |
|||
Output Regulation Range |
47~56V |
|||
Stabilized Voltage Precision |
±1% (@ 90V-264Vac input, 100% load) |
|||
Line Regulation |
±0.5% (@ 90-264Vac input, 100% load) |
|||
Load Regulation |
±1% (@ 90-264Vac input, 0-100% load) |
|||
Output Start Time |
< 2S @ nominal input (100% load) |
|||
Output Hold Time |
> 20ms @ 115Vac, > 115 ms @ 230Vac (100% load) |
|||
Voltage Overshoot |
≤5% |
|||
Input |
Input Voltage Range |
90~264VAC |
||
Input Rated Voltage Range |
100~240VAC |
|||
Frequency Range |
47~63Hz |
|||
Rated Frequency |
50/60Hz |
|||
Starting Voltage |
90Vac |
|||
Efficiency |
93.5% |
|||
Input Current @25℃ |
<6A |
|||
Inrush Starting Current @25℃ |
<40A@300Vac Cold start |
|||
Power Factor |
> 0.99 @ 115Vac, > 0.93 @ 230Vac |
|||
Protection |
Output |
Over power |
576~720W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.) |
|
Over voltage |
58–60V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage. |
|||
Over current |
12~15A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode: Swing machine, Self-recovery after over-current released.) |
|||
Short circuit |
It can be short circuited for a long time and automatically recover after the short circuit is eliminated. |
|||
Operation Environment |
Operation Temperature and Humidity |
–40℃~70℃; 20%~95%RH |
||
Storage Temperature and Humidity |
–40℃~85℃; 10%~95%RH non-condensing |
|||
Temperature Coefficient |
±0.03%/℃(0~50℃) |
|||
Liberation |
Frequency range: 10 ~ 500Hz, Acceleration: 2G, Each sweep cycle 10min. Six sweeps along the X, Y, and Z axis |
|||
Surge |
Acceleration: 20G, Duration time: 11mS, Three shocks along X, Y and Z axis |
|||
Altitude |
2000m |
|||
Safety and EMC Standard @25℃ |
Security Standard |
GB4943/EN60950 ■Reference □Certification |
||
Dielectric Strength |
Input—Output:3KVac/10mA; Input–Case:1.5KVac/10mA; Output—Case:0.5KVDC/10mA Time for each testing is 1min. |
|||
Grounding Test |
Test Condition: 32A/2min; Ground bond: <0.1 ohms. |
|||
Leakage Current @25℃ |
Input to GND ≤3.5mA; Input to output ≤0.25mA (Input 264Vac, 63Hz) |
|||
Insulation Resistance |
Input—Output: 10M ohms; |
|||
EMI |
Conducted Interference |
EN55022, EN55024, FCC PART 15 CLASS B |
||
Radiated Interference |
EN55022, EN55024, FCC PART 15 CLASS B |
|||
Harmonic current |
EN61000-3-2 CLASS D |
|||
EMS |
Conducted Emission |
EN61000-4-6 Level3 |
||
Radiated Emission |
EN61000-4-3 Leve3 criterion B |
|||
Power Frequency Emission |
EN61000-4-8 Level3 |
|||
Electrostatic Emission |
EN61000-4-2 Level4 criterion B |
|||
EFT |
EN61000-4-4 Level4 criterion B |
|||
Surge |
EN61000-4-5 Level4 criterion B |
|||
Dip and Interruption |
EN61000-4-11 |
|||
Design MTBF |
100,000Hrs AT 25℃, MIL-217 Method 2 Components Stress Method |
|||
Dimensions (W*H*D) |
138.55*136.50*70.21mm |